| |
Course Contents |
| |
| S.No |
Course Name |
Course Contents |
| 01. |
Radiography Testing Level-1 |
- Basic Principle of Radiation
- Curies
- Specific Activity
- Interaction of Radiation with matter
- Composition of industrial X-Ray Film
- Characteristic (H-D) curve
- Image Quality Indicator (Pentrameter)
- Specific
- Discussion of specific procedures
- Calculation of SFD depending on the appropriate Geometrical
Unsharpness
Examinations:
- General
- Specific
- Practical Tests
Top |
 |
 |
 |
 |
 |
 |
| |
| |
| |
Level - II |
- Geometrical Unsharpness
- Geometric Exposure Principle
- Image Quality Indicator
- Darkroom Facilities, Techniques and Processing
- Controlling Personnel Exposure
Top |
 |
|
| 02. |
Ultrasonic Testing Level - I |
- Introduction
- Basic Principle of Acoustic
- Equipment Testing Method
- Calibration
- Straight Beam Examination to 3specific Procedure
- Angle Beam Examination
Top |
 |
| |
 |
| |
Level II |
- Review of Ultra sonic technique course.
- Evaluation of Base – material product forms.
- Evaluation of weldments
- Discontinuity detection
- Evaluation
Top |
 |
|
| 03.Liquid
Penetrant Testing Level - II |
| |
|
- Introduction
- Liquid Penetrant Processing
- Various Pentrant testing methods
- Liquid Pentrant test Equipments
- Selection of the Appropriate Penetrant Testing Methods
- Inspection and Evaluation of Indications
- Inspection Procedures and Standards
- Review
Top |
 |
| |
 |
| |
|
| 04. |
Magnetic Particle Testing
Level - II |
- Principles of Magnets and Magnetic Fields
- Characteristics of magnetic Fields
- Effects of Discontinuities of Materials
- Magnetization by means of Electric Current
- Selecting of the Proper Method of Magnetization
- Inspection Materials
- Principles of Demagnetization
- Indications and Interpretations
|
- Magnetic Particle Testing Equipment
- Types of Discontinuities Detected by Magnetic Particle
Testing
- Magnetic Particle Test
- Flux fields
- Effects of Discontinuities of Materials
- Magnetization by means of Electric Current
- Selecting of the proper Method of Magnetization
- Demagnetization Procedures
- Equipment
- Types of Discontinuities
- Evaluation Techniques
- Quality Control of Equipment and Procedures
|
|

|
| |
|
|
|
|
| 05. |
Leak Testing Level - I |
Fundamental in Leak Testing
:
- Introduction
- Leak Testing Fundamentals
Safety in Leak testing :
- Safety Considerations
- Safety Precautions
- Pressure Precautions
- Hazardous and Tracer Gas Safety
- Types of monitoring Equipment
- Safety Regulations
Leak Testing Methods :
- Methods and Major Techniques
- Leak Testing Method Course Outline
Top |
 |
| |
| |
| |
| |
| |
Level - II |
Principles of Leak Testing
:
- Introduction
- Physical principles in Leak Testing
- Principles of Gas Flow
Pressure and Vacuum Technology :
- Pressure Technology
- Vacuum Technology
Leak Test Selection :
- Choice of Leak Testing Procedure
Top |
 |
|
| 06. |
Visual Testing Level - II |
|
| |
- Introduction to visual testing
- Fundamentals of vision
- Test equipments
- Process and discontinues
- Inspection of weldments, forgings etc
|
- Review of level I theory
- Lighting fundamentals
- Material attributes
- Environment and physiological
- Visual perception
|
|
|
| |
|
|
|
| 07. |
Eddy Current ( Electromagn-etic Testing)
Level - I |
- Introduction to Electromagnetic Testing
- Electromagnetic Theory
Electromagnetic Technique :
- Readout Mechanism
- Types of Eddy Current Sensing Elements
- Types of Flux Leakage Sensing Elements
Top |
 |
| |
Level II |
Electromagnetic Evaluation
:
- Review of Electromagnetic Theory
- Factors That Affect Coil Impedance
- Factors That Affect Flux Leakage Fields
- Signal-to-Noise Ratio
- Selection of Test Frequency
- Selection of Method of Magnetization for Flux Leakage
Testing
- Coupling
- Field Strength and Its Selection
- Field Orientation for Flux Leakage Testing
Top |
| |
 |
|
| 08. |
INFRA-RED
AND THERMALTRAINING COURSE |
| The only Institute in India offering
Infra Red SNT - TC - 1 A Level 1 and Level 2 courses.
These courses are tailor-made to suit individual needs. Individual
attention and teaching is provided. |
|
| |
|
|
|
| Level 1 |
|
Duration |
5 days |
Course
Fee |
Rs 25,000/- |
Minimum
candidates |
8 Per Batch |
| Level 2 |
|
Duration |
5 days |
Course
Fee |
Rs 25,000/- |
Minimum
candidates |
8 Per Batch |
| |
|
Courses
will be conducted in the First and the Last week of every
month. |
| |
|
| 09. Netron Radiography |
|
 |
-
Introduction
-
Physical principles
-
Radiation Sources for
neutrons
a) Reactors
b) Accelerators
c) Isotopic Sources
-
Beam Design
-
Radiation Detection
-
Neutrons Radiographic
Process
-
Technique and calibration
-
Test Result interpretation
-
Advantages over conventional
-
Radiography
-
Personal Safety
& Radiation Protection
|
| 10. Acoustic Emission Testing |
|
|
-
Introduction
-
Principle of AE
-
Factors affecting AE
-
AE Sensors
-
Cables
-
Signal Detection Signal Conditioning
-
Source Location Techniques
-
Equipment Calibration
-
Loading Procedure
-
Data Display
-
Noise Sources
-
Ways to minimize noise
-
AE Application:
-
Crack Growth detection
-
Pressure Vessel Monitoring
-
Tank Bottom Corrosion
-
Air Craft application
-
Application in mine
-
Seismic applications
-
Leak detective Monitoring
|
|
|
|
|
| |
|
| Basic Vibration Analysis
Physics Course: Level - I |
|
|
- Readout Mechanism
- Types of Eddy Current Sensing Elements
- Types of Flux Leakage Sensing Elements
|
| |
|
| Level II |
|
|
Electromagnetic
Evaluation :
- Review of Electromagnetic Theory
- Factors That Affect Coil Impedance
- Factors That Affect Flux Leakage Fields
- Signal-to-Noise Ratio
- Selection of Test Frequency
- Selection of Method of Magnetization for Flux Leakage Testing
- Coupling
- Field Strength and Its Selection
- Field Orientation for Flux Leakage Testing
|